Displaying report 1-1 of 1.
Reports until 14:26, Thursday 22 June 2023
H1 ISC
elenna.capote@LIGO.ORG - posted 14:26, Thursday 22 June 2023 - last comment - 10:31, Monday 26 June 2023(70734)
Soft loop gains updated

The CSOFT P gain has been returned to 20, which is nominal for 60W. Trending back to our 60W configuration, we ran with DSOFT P gain of 2.5 and DSOFT Y gain of 5. These gains were raised to 20 each with the power up to 76W to improve stability. I have reduced these gains to 10. This should reduce any residual DSOFT coupling to DARM. I think we can operate with the even lower gains, but I want to be able to see a few more locks to confirm we are stable in the ASC before dropping those gains further.

This is updated in the guardian and observe SDF.

Comments related to this report
elenna.capote@LIGO.ORG - 10:31, Monday 26 June 2023 (70823)

I have lowered the DSOFT gains again by half so they are now both 5. This is 60W nominal for DSOFT Y, but still twice 60W nominal for DSOFT P (was 2.5). This is SDFed and updated in the guardian.

Displaying report 1-1 of 1.