Displaying report 1-1 of 1.
Reports until 16:00, Thursday 22 June 2023
H1 General
ryan.crouch@LIGO.ORG - posted 16:00, Thursday 22 June 2023 (70741)
OPS Thursday Day shift summary

TITLE: 06/22 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
SHIFT SUMMARY:

Lock #1:

Locked for 10:05 when I arrived.

Out of Observing at 17:15 for LSC FF injections LHO:70737, HAM1 FF LHO:70727, ITMY A2L LHO:70730, and PEM work, Jeff also turned off the CAL_AWG_LINES LHO:70724.

Turned on EX wifi for Robert at 19:54, turned it back off when he was done at 20:57 (He also swept the VEA on his exit).

In the CAL_AWG_LINES code, I changed the code so that IDLE is the nominal state so the node will report OK LHO:70736.

Back into Observing at 21:24, out at 22:44 for some more comissioning (MICHFF, more PEM, PSL ISS 2nd loop gain change).

LOG:                                                                                                                                                                                                                               

Start Time System Name Location Lazer_Haz Task Time End
16:22 VAC Travis EndY N Grab tools from mech room 16:52
17:16 CAL Gabriele, Elenna Remote N LSC FF injections 17:58
17:47 VAC Travis, Janos MidX N Mech room 18:25
18:08 CAL Elenna Remote N ITMY A2L measurement 18:42
18:44 PEM Robert CR N PEM tests 20:44
19:39 PEM Robert EndX N PEM tests' 20:57
20:58 CAL Elenna, Gabriele Remote N FF test 21:24
21:50 VAC Gerardo EndY N Search for pump parts, valve room 22:20
22:44 CAL Elenna Remote N MICHFF test 22:48
22:45 PEM Robert LVEA N Prep measurement 22:53
22:53 PEM Robert CR N PEM tests On going
Displaying report 1-1 of 1.