I did cleanup on the HxTS screens in /opt/rtcds/userapps/trunk/sus/common/medm/hxts as for TMTS, OMCS, BSFM, HAUX, HTTS and QUAD.
As usual the main goal was to make all the link arguments look similar to the following (text editor view of .adl file), plus any other appropriate fixes:
args="%(read $(USERAPPS)/sus/common/medm/sus$(optic)_overview_macro.txt),USERAPPS=$(USERAPPS),SITE=$(SITE),site=$(site),IFO=$(IFO),ifo=$(ifo)"
Details:
No change (already OK): SUS_CUST_HLTS_M1_OPTICALIGN.adl, SUS_CUST_HLTS_M3_OPLEV_MTRX.adl, SUS_CUST_HLTS_M3_OPLEV_SEGS.adl, SUS_CUST_HXTS_M3_WD_OPLEV_BANDLIM.adl, SUS_CUST_BSFM_ODC.adl, SUS_CUST_HSTS_M1_OPTICALIGN.adl, SUS_CUST_BSFM_ODC.adl, SUS_CUST_HXTS_ADC_MONITOR.adl, SUS_CUST_HXTS_BIO.adl, SUS_CUST_HXTS_DAC_MONITOR.adl, SUS_CUST_HXTS_IPC.adl, SUS_CUST_HXTS_M1_CART2EUL.adl, SUS_CUST_HXTS_M1_CENTERING.adl, SUS_CUST_HXTS_M1_OSEM_ALIGN_??ZOOM.adl, SUS_CUST_HXTS_M1_COILOUTF.adl, SUS_CUST_HXTS_M1_DAMP.adl, SUS_CUST_HXTS_M1_DRIVEALIGN.adl, SUS_CUST_HXTS_M1_EUL2CART.adl, SUS_CUST_HXTS_M1_EUL2OSEM.adl, SUS_CUST_HXTS_M1_ISIINF.adl, SUS_CUST_HXTS_M1_LOCK.adl, SUS_CUST_HXTS_M1_OFFLOAD.adl, SUS_CUST_HXTS_M1_OPTICALIGN.adl, SUS_CUST_HXTS_M1_OSEM2EUL.adl, SUS_CUST_HXTS_M1_OSEMINF.adl, SUS_CUST_HXTS_M1_SENSALIGN.adl, SUS_CUST_HXTS_M1_TEST.adl, SUS_CUST_HXTS_M1_WD_ACT_BANDLIM.adl, SUS_CUST_HXTS_M1_WD_OSEMAC_BANDLIM.adl, SUS_CUST_HXTS_M1_WD_OSEMDC_BANDLIM.adl, SUS_CUST_HXTS_M2_COILOUTF.adl, SUS_CUST_HXTS_M2_DRIVEALIGN.adl, SUS_CUST_HXTS_M2_EUL2OSEM.adl, SUS_CUST_HXTS_M2_LOCK.adl, SUS_CUST_HXTS_M2_OSEM2EUL.adl, SUS_CUST_HXTS_M2_OSEMINF.adl, SUS_CUST_HXTS_M1_SENSALIGN.adl, SUS_CUST_HXTS_M2_TEST.adl, SUS_CUST_HXTS_M2_WD_ACT_BANDLIM.adl, SUS_CUST_HXTS_M2_WD_OSEMAC_BANDLIM.adl, SUS_CUST_HXTS_M2_WD_OSEMDC_BANDLIM.adl, SUS_CUST_HXTS_M3_COILOUTF.adl, SUS_CUST_HXTS_M3_DRIVEALIGN.adl, SUS_CUST_HXTS_M3_EUL2OSEM.adl, SUS_CUST_HXTS_M3_ISCINF.adl, SUS_CUST_HXTS_M3_LOCK.adl, SUS_CUST_HXTS_M3_OSEM2EUL.adl, SUS_CUST_HXTS_M3_OSEMINF.adl, SUS_CUST_HXTS_M3_OSEMOUTF.adl, SUS_CUST_HXTS_M3_SENSALIGN.adl, SUS_CUST_HXTS_M3_TEST.adl, SUS_CUST_QUAD_M3_WD_ACT_BANDLIM.adl, SUS_CUST_QUAD_M3_WD_OSEMAC_BANDLIM.adl, SUS_CUST_QUAD_M3_WD_OSEMDC_BANDLIM.adl, SUS_CUST_HXTS_MONITOR_OVERVIEW.adl, SUS_CUST_MC1_DAC_MONITOR.adl, SUS_CUST_MC2_DAC_MONITOR.adl, SUS_CUST_MC3_DAC_MONITOR.adl
Basic cleanup: SUS_CUST_HLTS_M3_OPLEV.adl, SUS_CUST_HLTS_M3_WD.adl, SUS_CUST_HLTS_OVERVIEW.adl, SUS_CUST_HSTS_M3_WD.adl, SUS_CUST_HSTS_OVERVIEW.adl, SUS_CUST_HXTS_DACKILL.adl, SUS_CUST_HXTS_M1_WD.adl, SUS_CUST_HXTS_M2_CENTERING.adl, SUS_CUST_HXTS_M2_WD.adl, SUS_CUST_HXTS_M3_CENTERING.adl, SUS_CUST_HXTS_M3_WD.adl
SUS_CUST_HXTS_M2_OSEM_ALIGN_??ZOOM.adl, SUS_CUST_HXTS_M3_OSEM_ALIGN_??ZOOM.adl: move to left screen
All updates were committed. This completes the screen cleanup. LLO can svn up the lot.