Reports until 00:11, Tuesday 27 June 2023
H1 General
camilla.compton@LIGO.ORG - posted 00:11, Tuesday 27 June 2023 - last comment - 01:42, Tuesday 27 June 2023(70842)
OPS Owl Shift Start

TITLE: 06/27 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 137Mpc
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 6mph Gusts, 4mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.05 μm/s 
QUICK SUMMARY: In NLN for 5h45. ITMY Mode5/6 violins slightly high

Dust monitors, SUS, SEI, CDS, VAC okay. Our DMT online.ligo.org/ "Observe" data isn't updating.

Comments related to this report
camilla.compton@LIGO.ORG - 01:42, Tuesday 27 June 2023 (70846)SUS

ITMY modes 5/6 damped fine once I engaged the nominal damping settings (IY05 @ -0.04). As the modes were rang up the VIOLIN_DAMPING guardian had set IYmode5 gain to "max_gain" value of 0, we could change this to -0.04 or -0.01, tagging SUS. 

Images attached to this comment