bricemichael.williams@LIGO.ORG - posted 13:56, Tuesday 27 June 2023 (70882)
Implemented Guardian ISC_LOCK code update

Implemented my code to speed up lockloss down time in the ACQUIRE_DRMI_1F and ACQUIRE_PRMI checks with a successful run!

Changes made to my code since previous post (70765):

In ACQUIRE_DRMI_1F, switched to check POPAIR_B_RF18_I_ERR_DQ data instead of POPAIR_B_RF90_I_ERR_DQ and lowered max threshold to 130 from 200. Changes made due to better correlation between RF18 and DRMI.

 

Code is easy to update if better thresholds are found.