Implemented my code to speed up lockloss down time in the ACQUIRE_DRMI_1F and ACQUIRE_PRMI checks with a successful run!
Changes made to my code since previous post (70765):
In ACQUIRE_DRMI_1F, switched to check POPAIR_B_RF18_I_ERR_DQ data instead of POPAIR_B_RF90_I_ERR_DQ and lowered max threshold to 130 from 200. Changes made due to better correlation between RF18 and DRMI.
Code is easy to update if better thresholds are found.