TITLE: 06/30 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 143Mpc
SHIFT SUMMARY:
Sheila was able to fix the issue with the EX PLL Beatnote by making adjustments to the ALSx laser.
LOCK #1: 1850-2221utc
- For this lock, held at LOCKING ARMS GREEN so Sheila could make adjustments to the ALSx laser to fix the EX PLL low beatnote (or FIBER_A_DEMOD_RFMON). Once this was improved, took H1 to NOMINAL LOW NOISE and it almost made it there without intervention, BUT....
- H1 was stuck at OMC WHITENING due to rung up violins
- Oli and I then focused on damping violins. Guardian thought the NOMINAL gains were a bit high, so we slowly brought up all gains to their NOMINAL values----this took about 1hr.
- Once the Violin Damping gains were all at their NOMINAL values, we made it to NLN, but within seconds there were DCPD saturations, rung-up violins, & some rung up PI modes---H1 was not happy!
- H1 did not like the extra gain of OMC WHITENING.
- TJ had us take the OMC_LOCK node from READY TO HANDOFF down to READY W NO WHITENING, and this removed gain from H1. We then waited for violins to calm down for about 30min.
- OMC LOCK was then taken back to READY FOR HANDOFF once again. This rung up violins up a little again, but after a few minutes we finally....
- 2221 Took H1 to OBSERVING (Violins were still a bit high, but have been slowly ringing down.)
- Since ALSx beatnote was fixed, for SDF, I needed to ACCEPT H1:ALS-X_FIBR_LOCK_BEAT_RFMIN original value of -10.0 (it was changed to -20.0 yesterday as a band-aid for the ALSx PLL issue.
LOG:
- 1545-1609 EY pump check (janos)
- 1722-1733 H2 Elec Room cleaning (kim)
- 1849 H1 lockloss (after 17hrs of lock)
- Took this opportunity to hit "COEFF LOAD" button for LSC model on CDS Overview, at Dave's request. (This is due to a new filter [FM3] for MICH FF). This filter isn't used, but it was a configuration change which showed up as a RED CFC box for LSC.
- 1855-1950 EX VAC checks (gerardo, jordan)
- 1925 ALSx Laser adjustments at EX (Sheila & a small crew)