PSL Status FAMIS Report for this week:
Laser Status:
NPRO output power is 1.829W (nominal ~2W)
AMP1 output power is 67.26W (nominal ~70W)
AMP2 output power is 135.5W (nominal 135-140W)
NPRO watchdog is GREEN
AMP1 watchdog is GREEN
AMP2 watchdog is GREEN
PMC:
It has been locked 8 days, 22 hr 37 minutes
Reflected power = 16.31W
Transmitted power = 109.1W
PowerSum = 125.4W
FSS:
It has been locked for 0 days 17 hr and 8 min
TPD[V] = 0.8459V
ISS:
The diffracted power is around 2.5%
Last saturation event was 0 days 17 hours and 8 minutes ago
Possible Issues: None