Displaying report 1-1 of 1.
Reports until 17:04, Tuesday 04 July 2023
H1 General (Lockloss, SQZ)
camilla.compton@LIGO.ORG - posted 17:04, Tuesday 04 July 2023 - last comment - 18:33, Tuesday 04 July 2023(71057)
Lockloss @ 22:22, Back to Observing 23:47UTC

Tony had a lockloss that the lockloss tool tagged with a DCPD saturation (our 11 most recent NLN locklosses have been too) 1372544545.

Waited ISC_LOCK waited 20 minutes in OMC_WHITENING for lots of violins to damp. The VOILIN_DAMPING guardian had turned down the gain on EY08 as it was rung up but the damping OUTMON reduced quickly <100 so I increased the gain back to it's nominal for faster damping. Lots of voilins are still rung up and slowly damping, see attached.

SQZ_MANAGER had message "SQZ ASC AS24 not on??" so I took SQZ_MANAGER to NO_SQUEEZING, gracefully cleared the A42 history (sitemap > SQZ > SQZ Overview > IFO ASC > ! graceful clear history) and then SQZ_MANAGER to FREQ_DEP_SQZ. This has happened a couple of times recently 70890 but Vicky and Naoki plan to look into this or automate this week. Tagging SQZ.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 18:33, Tuesday 04 July 2023 (71058)

It seems the OMC_DCPD tag has only been on the last locklosses since the violins have been rung up (2023/06/29 70945, 70943), see attached. The OMC overflows  H1:FEC-8_ADC_OVERFLOW_0_{12,13} haven't dropped back down to zero and the lockloss tool just looks for these channels being non-zero before the lockloss.

This 22:22UTC lockloss has an unknown-for-now cause. Nothing in ASC, LSC, no violin saturations or PIs, not the IMC.

Images attached to this comment
Displaying report 1-1 of 1.