Reports until 14:13, Wednesday 05 July 2023
H1 CDS
david.barker@LIGO.ORG - posted 14:13, Wednesday 05 July 2023 - last comment - 14:53, Wednesday 05 July 2023(71075)
h1guardian1 gpstime reporting expired leap-seconds file

Erik, TJ, Dave:

TJ found that gpstime on h1guardian1 is warning of an expired leapseconds file. The file in question is /usr/share/zoneinfo/leapseconds which has an expiration time of 1687910400 in UNIX seconds which is Tue 27 Jun 2023 05:00:00 PM PDT.

Currently H1 is locked for commissioning, so we don't want to do any updates on h1guardian1 at this time. As a temporary measure I increased the expiration time to 1787910400, Fri 28 Aug 2026 02:46:40 AM PDT by manually editing the file.

Comments related to this report
jameson.rollins@LIGO.ORG - 14:53, Wednesday 05 July 2023 (71077)

This is handled by the tzdata debian package on the guardian machine.