Displaying report 1-1 of 1.
Reports until 23:53, Thursday 06 July 2023
H1 DetChar
kamiel.janssens@LIGO.ORG - posted 23:53, Thursday 06 July 2023 (71130)
Broadband jitter noise (100-200Hz)

When using the Carleton linefinder tool (which Daniel Nykamp is further developing) following up some lines for stochastic searches I came across loud and broadband coherence in H1:IMC-F_OUT_DQ with CAL-DELTAL_EXTERNAL, see figure 1 (produced by FScan, provided by the linefinder tool).

Andrew Ludgren confirmed the same coherence is also visible with GDS-CALIB_STRAIN_CLEAN and the noise sources was identified as jitter, see: https://ldvw.ligo.caltech.edu/ldvw/view?act=getImg&imgId=361570

 

Images attached to this report
Displaying report 1-1 of 1.