Displaying report 1-1 of 1.
Reports until 08:16, Saturday 08 July 2023
H1 SEI
austin.jennings@LIGO.ORG - posted 08:16, Saturday 08 July 2023 (71157)
SEI Ground Seismometer Mass Position Check - Monthly

Closes FAMIS 25713, last completed on June 5th

There are 11 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.723 [V]
ETMX T240 2 DOF Y/V = -0.826 [V]
ITMX T240 1 DOF X/U = -0.678 [V]
ITMX T240 1 DOF Z/W = 0.416 [V]
ITMX T240 3 DOF X/U = -0.65 [V]
ITMY T240 3 DOF X/U = -0.468 [V]
ITMY T240 3 DOF Z/W = -0.877 [V]
BS T240 1 DOF Y/V = -0.424 [V]
BS T240 3 DOF Y/V = -0.386 [V]
BS T240 3 DOF Z/W = -0.54 [V]
HAM8 1 DOF Z/W = -0.409 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = 0.15 [V]
ETMX T240 1 DOF Y/V = 0.108 [V]
ETMX T240 1 DOF Z/W = 0.115 [V]
ETMX T240 2 DOF Z/W = -0.273 [V]
ETMX T240 3 DOF X/U = 0.09 [V]
ETMX T240 3 DOF Y/V = 0.054 [V]
ETMX T240 3 DOF Z/W = 0.092 [V]
ETMY T240 1 DOF X/U = 0.036 [V]
ETMY T240 1 DOF Y/V = 0.061 [V]
ETMY T240 1 DOF Z/W = 0.12 [V]
ETMY T240 2 DOF X/U = -0.073 [V]
ETMY T240 2 DOF Y/V = 0.139 [V]
ETMY T240 2 DOF Z/W = 0.069 [V]
ETMY T240 3 DOF X/U = 0.126 [V]
ETMY T240 3 DOF Y/V = 0.054 [V]
ETMY T240 3 DOF Z/W = 0.101 [V]
ITMX T240 1 DOF Y/V = 0.29 [V]
ITMX T240 2 DOF X/U = 0.097 [V]
ITMX T240 2 DOF Y/V = 0.189 [V]
ITMX T240 2 DOF Z/W = 0.198 [V]
ITMX T240 3 DOF Y/V = 0.122 [V]
ITMX T240 3 DOF Z/W = 0.131 [V]
ITMY T240 1 DOF X/U = 0.038 [V]
ITMY T240 1 DOF Y/V = -0.017 [V]
ITMY T240 1 DOF Z/W = -0.129 [V]
ITMY T240 2 DOF X/U = 0.073 [V]
ITMY T240 2 DOF Y/V = 0.146 [V]
ITMY T240 2 DOF Z/W = -0.032 [V]
ITMY T240 3 DOF Y/V = 0.002 [V]
BS T240 1 DOF X/U = -0.262 [V]
BS T240 1 DOF Z/W = 0.002 [V]
BS T240 2 DOF X/U = -0.157 [V]
BS T240 2 DOF Y/V = -0.073 [V]
BS T240 2 DOF Z/W = -0.257 [V]
BS T240 3 DOF X/U = -0.281 [V]
HAM8 1 DOF X/U = -0.239 [V]
HAM8 1 DOF Y/V = -0.203 [V]

Assesment complete.

 

All STSs prrof masses that within healthy range (< 2.0 [V]). Great!


Here's a list of how they're doing just in case you care:
STS A DOF X/U = -0.579 [V]
STS A DOF Y/V = -0.756 [V]
STS A DOF Z/W = -0.601 [V]
STS B DOF X/U = 0.486 [V]
STS B DOF Y/V = 0.793 [V]
STS B DOF Z/W = -0.338 [V]
STS C DOF X/U = -0.426 [V]
STS C DOF Y/V = 0.952 [V]
STS C DOF Z/W = 0.151 [V]
STS EX DOF X/U = -0.103 [V]
STS EX DOF Y/V = 0.071 [V]
STS EX DOF Z/W = 0.079 [V]
STS EY DOF X/U = 0.24 [V]
STS EY DOF Y/V = -0.885 [V]
STS EY DOF Z/W = 0.973 [V]
STS FC DOF X/U = 0.38 [V]
STS FC DOF Y/V = -0.796 [V]
STS FC DOF Z/W = 0.734 [V]