Reports until 18:52, Wednesday 17 July 2013
H1 SEI
vincent.lhuillier@LIGO.ORG - posted 18:52, Wednesday 17 July 2013 (7118)
BSC-ISIs controlled for the night

Today, on BSC-ISIs:
- Calibration filters were reinstalled (the minus gain of the HEPI L4C is introduced in the calibration filter)
- The feedforward controllers were retuned/reinstalled on the 3 BSC-ISIs (The gain is 1 when engaged)
- The sensor correction filters were retuned/reinstalled on the 3 BSC-ISIs

At 18h50 PT:
- HEPI BSC6 and BSC2 are controlled in position
- ISI BSC6 and ISI BSC1 are controlled with
    - Feedforward ST0->ST1
    - Damping
    - Feedback Level 3
    - Sensor correction Stage 1 X,Y,Z
    - Sensor correction Stage 2 Y

ISI-BSC2 controlled with
    - Feedforward ST0->ST1
    - Damping