Reports until 04:00, Monday 10 July 2023
H1 General
ryan.crouch@LIGO.ORG - posted 04:00, Monday 10 July 2023 - last comment - 04:32, Monday 10 July 2023(71191)
OPS Monday owl midshift update

We had a lockloss at 07:57, relocking was mostly automated I only had to intervene to help Xarms PLL lock. I had to hold in OMC_WHITENING for about 1.5 hours for the violins to damp. Back in NLN and Observing as of 11:00 UTC.

Comments related to this report
rahul.kumar@LIGO.ORG - 04:32, Monday 10 July 2023 (71192)SUS

I ramped up the gains for many of the rung up modes (see screenshot of the DARM spectra for 500Hz and kHz modes), however it still needed around 1-2hrs of before DCPD counts were below 500K counts (for Nominal Low Noise state). All gains are currently set to their nominal values.

Images attached to this comment