Damping ETMY mode 20 and high resolution spectra for modes in kHz region (1500-2000Hz)

ETMY mode 20 had no damping settings in the Guardian and the mode was rung up. I applied the following settings and it has worked during this lock stretch. I will add it to the Guardian and accept them in the SDF once I am confident that the settings work consistently.

FM1 FM4 FM10 Gain -1.0

The above filters were already engaged, hence I only had to look for an appropriate gain and this didn't kick us out of Observing.

Also, Jenne wanted some of the higher order modes to be looked into and damped (see her alog 71212). I took high resolution spectra for modes between 1500Hz and 2000Hz and have been working on identifying (frequencies and which optic it belongs to) the top few rung up modes. Once identified, I will start looking for damping settings for the same.