Coherences after OM2 change

DARM coherences after OM2 was turned off and is now cold: https://ldas-jobs.ligo-wa.caltech.edu/~gabriele.vajente/bruco_DARM_1373284789_COLDOM2/ 

It looks like the low frequency noise has now higher than usual coherence with:
DHARD_Y: https://ldas-jobs.ligo-wa.caltech.edu/~gabriele.vajente/bruco_DARM_1373284789_COLDOM2/ASC-DHARD_Y_IN1_DQ.html
MICH: https://ldas-jobs.ligo-wa.caltech.edu/~gabriele.vajente/bruco_DARM_1373284789_COLDOM2/LSC-MICH_OUT_DQ.html
PRCL: https://ldas-jobs.ligo-wa.caltech.edu/~gabriele.vajente/bruco_DARM_1373284789_COLDOM2/LSC-PRCL_OUT_DQ.html

and adding jitter coherence for reference: https://ldas-jobs.ligo-wa.caltech.edu/~gabriele.vajente/bruco_DARM_1373284789_COLDOM2/PEM-CS_ACC_PSL_TABLE1_X_DQ.html

Comments related to this report
jenne.driggers@LIGO.ORG - 14:10, Thursday 13 July 2023 (71300)

These excess coherences are also evident in our range (as has been mentioned elsewhere in the alog).

In the attached figure, I show both the 'usual' range that's on the wall in the control room in blue, as well as the range calculated from the GDS-CALIB_STRAIN channel (it's probably actually the CLEAN version of GDS).

We turned on the OM2 heater at the time of the T-cursor around -16 days.  Prior to this time, the CAL-DELTAL channel was well matched to the GDS-CALIB_STRAIN calibration, so blue and orange overlap nicely.  The lower Y-cursor is roughly around the middle of our range values for the past OM2-cold times. 

During the time that OM2 was hot (up until about -1 day on this plot), both versions of the range are higher than before, although the orange calculation that takes into account our optical gain loss shows a more modest improvement than what we see on the wall (blue trace).  The upper Y-cursor is roughly around the middle of the corrected-for-optical gain orange trace.

We turned OM2's heater off yesterday, and so we're back to the calibration situation where CAL-DELTAL matches GDS-CALIB.  But, it's clear that both versions of our range are dramatically lower today than they were the last time we had OM2 cold.  Reasons for this are still under investigation. 

Images attached to this comment