Reports until 22:54, Thursday 18 July 2013
H1 AOS
lisa.austin@LIGO.ORG - posted 22:54, Thursday 18 July 2013 (7131)
SLC - Manifold Cryopump assembly and installation & Arm Cavity Baffle assembly
Mitchell Robinson, Scott Shankle, Mike Vargas, Thomas Vo and Apollo's Tyler

Manifold Cryopump for ETMx -
Tyler modified 20 FHCS 1/2-13 and submitted for Class A clean and bake. Reviewed specifications for 'Made in India' group of screws for acceptability. Determined parts are ANSI qualified SSTL.
ECR E1200612 was submitted and approved. Scott submitted design of spacer. Part fabrication in process; aim is to Class A by installation on Tuesday.


Arm Cavity Baffle for ETMx -
Started upgrading Arm Cavity Baffle from BSC8 to install in BSC9. Completed Spring Blade Assembly.