Reports until 15:06, Friday 14 July 2023
H1 CDS
david.barker@LIGO.ORG - posted 15:06, Friday 14 July 2023 - last comment - 10:08, Saturday 15 July 2023(71335)
Restart of psinject on h1hwinj1 at 13:21 PDT, memory leak fixed

WP11290 Revert LALAPPS to fix memory leak

Erik, Dave:

At 13:21 PDT Erik restarted the psinject CW process on h1hwinj1 after downgrading the libSIStr,so library file. This has fixed the memory leak h1hwinj1 has had since its upgrade when tconvert was replaced by gpstime.

Between 13:21 and 14:48 there has been no additional memory allocated, before memory was used at a rate of 3.5MB/min.

We will run with this over the weekend and if it all looks good I will revert the h1calinj SDF change make to permit INJ_CW GAIN and TRAMP changes while in observation (WP11304)

6 hour trent of INJ_CW with restart shown in attachment.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 10:08, Saturday 15 July 2023 (71350)

Memory usage unchanged overnight, looks like leak has definitely been fixed.