(Robert, Stefan) I calibrated the REFLAIR_A_RF9 diode: - gain: 82Hz/(2*1000cts) (see Alexa's elog from last week, but the amount of light we get changed slightly) - Cavity pole compensation zero at 82Hz. With the PSL in science mode, here is the noise performance we get. We get a significant improvement between 2Hz and 60Hz due to the lower PSL noise. Also the noise at 0.44Hz is slightly lower on the PDH signal (not surprising - it's caused by alignment fluctuations). The traces are: - Red: REFLAIR_A_RF9 in low bandwidth configuration (on center fringe) - Blue: ASC-y_TR_A_NSUM_OUT in low bandwidth configuration (on half fringe) - Green: REFLAIR_A_RF9 in high bandwidth configuration (on center fringe) - Gold: Best curve before PSL work (July 8) - The total RMS of the red trace is 3.5Hz, 3Hz above 0.5Hz.