Reports until 16:09, Saturday 15 July 2023
H1 General (PSL)
camilla.compton@LIGO.ORG - posted 16:09, Saturday 15 July 2023 - last comment - 08:41, Sunday 16 July 2023(71357)
OPS Day Shift Summary

TITLE: 07/15 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 132Mpc
SHIFT SUMMARY: Been in NLN 1h55, still haven't had a TOO to take the 'pydarm measure --run-headless bb' calibration measurement.
LOG:

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 08:41, Sunday 16 July 2023 (71373)PSL

Looking into IMC_LOCK "Diffracted power jumped too much, toggling secondloop" message. In this 07/15 20:02UTC lock the CLOSE_ISS state worked on it's fourth attempt, see attached.

Since then it has worked on the first (07/16 11:41UTC) and second (07/16 13:50UTC) attempts. Before this it worked on the first (07/14 23:21UTC) (07/14 17:15UTC), second (07/14 12:25UTC) and fifth (07/13 09:14UTC) attempts.

Maybe this is expected but should be looked into, may be related to low ISS diffracted power issue Jason will fix this week (71322).

Images attached to this comment