gabriele.vajente@LIGO.ORG - posted 11:53, Wednesday 19 July 2023 - last comment - 12:41, Wednesday 19 July 2023(71505)
DHARD_Y motion upconvert noise into DARM

Yesterday I did a DHARD_Y noise injection that had band-limited noise between 1.5 and 3.5 Hz. In the first plot I compare ASC-DHARD_Y and LSC-DARM in quiet times and during the injection.

There are several interestiing observations:

This is good evidence that DHARD_Y is causing some non-linear noise coupling in DARM. This is also visible in the bicoherence of DARM with itself or of DHARD_Y and DARM.

It would be interesting to repeat similar noise injections, but with shaped noise and amplitudes such to increase only slighlty the DHARD_Y signal: in this way we might be able to estimate the efffect on DARM in normal conditions.

Images attached to this report
Comments related to this report
peter.fritschel@LIGO.ORG - 12:41, Wednesday 19 July 2023 (71508)

Given this finding, I was curious to see how CHARD_Y compared between H1 and L1. Attached are comparison spectra from an Observe mode lock a couple of days ago. There's nothing really suspiciously different between the two. There's a 1.5 Hz peak prominent in H1 but not L1, and the L1 noise above 15 Hz is much lower due to the more aggressive low-pass filtering.