Displaying report 1-1 of 1.
Reports until 06:56, Thursday 20 July 2023
H1 ISC
ryan.short@LIGO.ORG - posted 06:56, Thursday 20 July 2023 - last comment - 11:48, Thursday 20 July 2023(71538)
TOO - MICHFF Measurement

While LLO was relocking this morning, I dropped observing from 13:44 to 13:54 UTC to run Gabriele's MICH FF template with 35 averages.

The measurement is saved in /ligo/home/ryan.short/MICH_excitation_2023_07_20.xml

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 07:58, Thursday 20 July 2023 (71540)

Using this measurement, I retuned the MICH FF. The new filter is FM6 '7-20-23'. The attached plots show the fit and a comparison of the performance of the new filter and the old. There's a lot of improvement above 60 Hz, and a few db improvement below 60 Hz

Images attached to this comment
ryan.short@LIGO.ORG - 08:14, Thursday 20 July 2023 (71542)

I've accepted the new FM6 filter in SDF as well as updated and loaded ISC_LOCK to use this filter when locking.

gabriele.vajente@LIGO.ORG - 08:25, Thursday 20 July 2023 (71544)

Here's a plot showing the DARM improvement with the new MICH FF, that gave us about +6 Mpc

Images attached to this comment
gabriele.vajente@LIGO.ORG - 09:30, Thursday 20 July 2023 (71547)

Here's a second iteration of the MICH FF, with much better performance below 60 Hz and marginally worse above 60 Hz. I think this is a better FF, so we'll leave it running as FM7 '7-20b-23'. ISC_LOCK has been updated

Images attached to this comment
jenne.driggers@LIGO.ORG - 11:48, Thursday 20 July 2023 (71550)

Here is a different view of the impact of Gabriele's MICH FF tuning this morning.  Seafoam and purple are the same as in alog 71529, and red is today after the MICH FF tuning.  All of these are with hot OM2 and no MICH ASC offsets. Seafoam is late June, purple is yesteray, and red is today.  Red only has 94 averages because there were other commissioning tasks ongoing, but the other two both have 200 avgs.

The MICH FF tuning got us all the way back to where we were in June, with the excellent ~70 Hz sensitivity.  There is still some jitter-like noise, but that is unchanged from yesterday.

Images attached to this comment
Displaying report 1-1 of 1.