Reports until 14:55, Thursday 20 July 2023
H1 ISC (SUS)
camilla.compton@LIGO.ORG - posted 14:55, Thursday 20 July 2023 - last comment - 21:17, Monday 24 July 2023(71559)
DHARD_Y Transient during DHARD_WFS state, larger since June 29th.

Daniel, Camilla 

Following on from Ryan's 71420, we looked at the movement of ITMY (only has ASC control) during DHARD_WFS and see there is now larger spikes during locking than before 29th, see attached plot where H1:SUS-ITMY_L2_OSEMINF_{U,L}{L,R}_INMON spikes during locking are larger after the t-cursor (see bottom purple plot for when violins rang up).

Zooming in, attached plot, we can see when the Input to the DHARD_Y filter is turned on that the output to DHARD_Y filter has a large transient lasting ~1second, not seen in DHARD_Y inmon. The only filter that is on during that time FM6 and although it has a larger step response, there is a 5s TRAMP so Daniel doesn't see an issue with this.

Nothing obvious happened to DHARD on the 29th, only alog around that date shows a change that was reverted 70928.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 14:09, Monday 24 July 2023 (71655)

During relock on Tuesday we plan to increase this DHARD_Y ramp time (currently 5s) to see if we can reduce this transient that appears to have increased by a factor of 10 around June 29th. See attached plots of relock before and after the violins rang up.

Images attached to this comment
oli.patane@LIGO.ORG - 21:17, Monday 24 July 2023 (71672)

There were some SDF Diffs (71670) for H1:ASC-DHARD_Y_TRAMP and H1:ASC-DHARD_P_TRAMP that I accepted, which bumped the ramp times up to 15 seconds.

Images attached to this comment