Displaying report 1-1 of 1.
Reports until 12:37, Thursday 20 July 2023
H1 General (Lockloss)
anthony.sanchez@LIGO.ORG - posted 12:37, Thursday 20 July 2023 - last comment - 15:56, Thursday 20 July 2023(71553)
Thursday Lockloss report.

First Lockloss of the Day: 18:14 UTC
Lockloss tool failed on analyze of this LockLoss. 
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1373912078
Happened while the PEM crew were potentially working around HAM2's sensitive areas. Possibly could have been them.

Screen shot of lockloss select's ndscopes attached.

Images attached to this report
Comments related to this report
anthony.sanchez@LIGO.ORG - 15:56, Thursday 20 July 2023 (71568)Lockloss

The second Lockloss: 19:25 UTC Lock loss was certainly due to a button being pressed that then caused a lockloss.
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1373916371

"When I set H1:LSC-MICHFF_GAIN back to 1 from zero, we lost lock
This is because I had FM7 and FM6 on in that filter bank, when I should only have had FM7."
~The button pusher.


The third lockloss was immediately afterwards: Was from OFFLOAD_DRMI and almost certainly cause by poor alignment.
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1373916371

Images attached to this comment
Displaying report 1-1 of 1.