Displaying report 1-1 of 1.
Reports until 00:01, Friday 21 July 2023
LHO General (OpsInfo, SUS)
austin.jennings@LIGO.ORG - posted 00:01, Friday 21 July 2023 (71570)
Thursday Eve Shift Summary

TITLE: 07/20 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 145Mpc
SHIFT SUMMARY:

- Started off the shift with a lockloss - cause unknown

- Reacquisition was automated, but we lost lock at TRANSITION FROM ETMX, EY/IX saturation

- Acquired NLN/OBSERVE @ 2:05

- I took a spectra of the 2nd harmonic violin modes - a current theory as to why the violins are ringing up is due to the 2nd order harmonics coupling into the first and fundamental modes, scope attached - Tagging SUS

- Note: The new H1 manager node we are testing automatically sets the requested state to be NLN, however due to the violin issue we have to wait in OMC WHITENING

- Leaving H1 to Ryan C. with the IFO locked and in observing for just under 5 hours

LOG:                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       

Start Time System Name Location Lazer_Haz Task Time End
23:45 VAC Gerardo EY N Check vacuum gauge 00:12
Images attached to this report