Displaying report 1-1 of 1.
Reports until 15:16, Tuesday 25 July 2023
H1 SQZ (ISC)
nikhil.mukund@LIGO.ORG - posted 15:16, Tuesday 25 July 2023 (71691)
OPO NLG gain & IFO sensitivity

[nikhil, vicky]

We looked at Saturday's corrective maintenance period (see Corey's entry: 71613), where the nonlinear gain of the OPO pump power was varied by changing the OPO ISS set points. NLG gain of close to 80 uW provides the best broadband squeezing. A higher power level seems to degrade the SQZ level and injects extra noise below 40 Hz. Currently, the non-linear gain is set to 50 uW.

UTC Dur (s) ISS Setpoints Plot label

Angle-averaged range [SNSL][Mpc]

2023-07-22 20:10:00 1200 - SQZ Off 136.8
2023-07-22 17:30:00 1200 50 uW NLG Low 140.5
2023-07-22 21:00:00 1200 80 uW NLG High 144.5
2023-07-22 12:30:00 1200 90 uW NLG Highest 145

 

 

 

Images attached to this report