Following on from 71381, today during commissioning time, I injected 2.6Hz sine wave into in H1:OMC-SUS_M1_TEST_{L, P, Y, V, T, R}_EXC by increasing gradually the gain until when we reach the peak-to-peak amplitude around 40 urad or 4um on the H1:OMC-SUS_M1_DAMP_{L, P, Y, V, T, R}_INMON channels.  I didn't get this amplitude in R or V due as any higher gain was causing DAC saturations. 

DARM plot attached during these times. Can see a lot of coupling with P, Y, L. Not anything easily noticeable with R, V, T.