HAM2 and HAM3 SEI Alignments

Prior to releasing HAM2 and HAM3 HEPIs, we recorded the readouts on the postion sensors of the ISIs, and HEPIs, of the input mode cleaner.

 

HAM2 ISI, raw CPS readouts, in counts

H1            -3388.2      

H2            -2936.6      

H3            -504.78      

V1           -138.78      

V2            -966.74      

V3            -737.11      

 

HAM3 ISI, raw CPS readouts, in counts

 H1           -526.93       

 H2           266.35         

 H3           -175.73        

 V1           -1405.1        

 V2           -1102.9        

 V3           -560.2          

 

HAM1 HEPI, raw IPS readouts, in counts

H1            8075.8         

H2            -2940.6       

H3            -8136.2       

H4            -1306.2       

V1            182.27         

V2            4545.2         

V3            -1657.4        

V4            -1572.6        

 

HAM2 HEPI, raw IPS readouts, in counts

H1            1331.1         

H2            957.72         

H3            2157.4         

 H4           -1303.6       

 V1           -2742.7       

 V2           -511.83        

 V3           1034             

 V4           -2882.9       

 

HAM3 HEPI, raw IPS readouts, in counts

H1            6517.4         

H2            -4677.9       

H3            9328.4        

H4            -2148.2       

V1            2864.2        

V2            -6362.4       

V3            2112.5         

V4            -9395.8       

Comments related to this report
hugo.paris@LIGO.ORG - 14:22, Tuesday 23 July 2013 (7182)

I made, and used, a script to retrevieve all this information at once:

/ligo/svncommon/SeiSVN/seismic/Common/MatlabTools/IMC_ISI_HEPI_position.m

It is commited under the SVN (r7458)