Reports until 18:09, Tuesday 23 July 2013
H1 SEI
hugo.paris@LIGO.ORG - posted 18:09, Tuesday 23 July 2013 - last comment - 18:14, Tuesday 23 July 2013(7189)
HAM2 HAM3 HEPI Release - IMC Alignment Reestablished

HAM2 and HAM3 HEPI were released today.

 

Raw IPS readouts were recorded prior to release. The following offests were set in the actuation path to reestablish alignment, based on the IPS readouts:

  OFFSETS (cnt)
  HAM2 HAM3
H1 370 900
H2 800 200
H3 -600 350
H4 -400 -650
V1 450 300
V2 460 -650
V3 1050 200
V4 900 1250

 

 

IPS readouts were recorded after reestablishing alignment:

 

  NEW READOUTS (cnt)
  HAM2 HAM3
H1 1438.7 6664
H2 957.61 -4089.2
H3 2089.2 9159.3
H4 -1238.1 -2252.5
V1 -2796.8 2709.1
V2 -608.92 -6394.7
V3 1029.5 2257
V4 -2862.8 -9434.1

 

 

The Before/After difference in IPS readout is shown below:

 

  BEFORE/AFTER DIFFERENCE (cnt)
  HAM2 HAM3
H1 107.6 146.6
H2 0.11 588.7
H3 68.2 169.1
H4 65.5 104.3
V1 54.1 155.1
V2 97.09 32.3
V3 4.5 144.5
V4 20.1 38.3

 

 

The remaining shift in alignment induced by unlocking HAM2 and HAM3 HEPI is less than 0.25mils (147 counts on the IPS), on each pier, after reestablishing the alignent with offsets on the actuation path.

Comments related to this report
hugo.paris@LIGO.ORG - 18:14, Tuesday 23 July 2013 (7190)

Note: Isolation loops tripped only on HAM2-ISI. They are back ON now.

The DC part of those loops (CPS Biases) remain unchanged from prior to HEPI release, hence ensuring consistent alignment of the platforms.