(Louis, Jeff K, Corey)
After addressing Gabriele overnight test SDF Diffs, now had alot of SDF diffs for CALEX & CALEY (basically PCAL channels). And on the DARM FOM, could not see any (green) PCALy lines or (pink) PCALx lines. At this point, started working with Louis on TeamSpeak and he started texting Kissel. Below is what I did (via Louis instructions) for the CALEY & CALEX SDF nodes:
H1CALEY:
- 26-Diffs were listed
- I forgot to take a screenshot of this before REVERTing, but attached is a photo Louis sent to me.
- REVERTED all 26 Diffs
- Clicked on "SDF RESTORE SCREEN" on CALEY
- Then on this window, Clicked "! SELECT REQUEST FILE"
- In pop-up window, selected "safe.snap" & clicked OPEN (this closes pop-up)
- Then on SDF RESTORE SCREEN, clicked "LOAD TABLE" and after a couple secondsit looks like the safe.snap was updated with a time stamp of Aug 2, 2023 at 18:25:59 (PT).
- With Louis on the phone texting with Jeff, we think we are good....we have green PCALy lines on DARM FOM.
H1CALEX:
- 16-Diffs were listed
- REVERTED all 16 Diffs
- Clicked on "SDF RESTORE SCREEN" on CALEX
- Then on this window, Clicked "! SELECT REQUEST FILE"
- In pop-up window, selected "safe.snap" & clicked OPEN (this closes pop-up)
- Then on SDF RESTORE SCREEN, clicked "LOAD TABLE" and after a couple secondsit looks like the safe.snap was updated with a time stamp of Aug 2, 2023 at 18:34:18 (PT).
- Louis continued texting with Jeff. The pink PCALx on DARM FOM might look odd....waiting to see what Kissel thinks.
- At this point, Louis and Kissel took over to restore PCALx....so I think we are about ready to go back to OBSERVING