gabriele.vajente@LIGO.ORG - posted 17:28, Wednesday 02 August 2023 - last comment - 18:56, Wednesday 02 August 2023(71918)
Commissioning tests

Several CHARD_Y tests today during the commissioning time. A more detailed analysis will follow.

Went go to NLN_CAL_MEAS

## Test new CHARD_Y ##
- load new filter OK
- engage with gain 60 OK
- gain increase to 100 looks OK: what is that big peak at 3.x Hz? It's not gain peaking of the CHARD_Y loop

## Check A2L ##
- inject line at 22.1 Hz and check demodulation of DARM. Large fluctaations, hard to tune
- inject noise [CHARD_Y noise ampl 20  butter("BandPass",6,10,100)]
  coupling at low frequency changes differently than high frequency (-1.50 is a good compromise). Also, 22 Hz is right at the transition between the two noise coupling regions

## Test Mass damping ##
- reduce gain looking at TM signals and also CHARD_Y DHARD_Y

all test mass M0 Y gains to -0.5
from PDT: 2023-08-02 16:23:37.085598 PDT
     UTC: 2023-08-02 23:23:37.085598 UTC
     GPS: 1375053835.085598
to   PDT: 2023-08-02 16:32:40.068152 PDT
     UTC: 2023-08-02 23:32:40.068152 UTC
     GPS: 1375054378.068152

left gains at -0.5

## PR3 damping gain reduction ##
M1 Y damping gain to -0.5
from PDT: 2023-08-02 16:33:56.677335 PDT
     UTC: 2023-08-02 23:33:56.677335 UTC
     GPS: 1375054454.677335
to   PDT: 2023-08-02 16:44:18.190283 PDT
     UTC: 2023-08-02 23:44:18.190283 UTC
     GPS: 1375055076.190283

     
Lowering the damping gains might have changed a bit the plant? Measured another CHARD_Y plant [saved CHARD_Y_shaped_exc_2023_08_02.xml]

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 18:11, Wednesday 02 August 2023 (71919)

When we got back to NLN, I implemented the changes below to test overnight
- CHARD_Y engage FM9, increase gain to 100
- ITMY Y2L to -1.500
- test mass M0 Y damp reduced to -0.5
- PR3 M1 Y damp reduced to -0.5

In case of a lock loss, all those changes will be reverted

gabriele.vajente@LIGO.ORG - 18:53, Wednesday 02 August 2023 (71921)

At a first glance there is some good improvement at low frequency.

Images attached to this comment
corey.gray@LIGO.ORG - 18:56, Wednesday 02 August 2023 (71922)ISC, SUS

Here are the SDF Diffs which needed to be ACCEPTED for Gabriele's overnight test.  These are for diffs for ASC, PR3 and all 4 Test Masses.