Displaying report 1-1 of 1.
Reports until 15:19, Friday 04 August 2023
H1 SEI
oli.patane@LIGO.ORG - posted 15:19, Friday 04 August 2023 (71967)
SEI Ground Seismometer Mass Position Check - Monthly - FAMIS #25714

Closes FAMIS #25714 , last completed on July 8th

T240:

There are 11 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.765 [V]
ETMX T240 2 DOF Y/V = -0.903 [V]
ITMX T240 1 DOF X/U = -0.744 [V]
ITMX T240 1 DOF Z/W = 0.403 [V]
ITMX T240 3 DOF X/U = -0.722 [V]
ITMY T240 3 DOF X/U = -0.509 [V]
ITMY T240 3 DOF Z/W = -0.936 [V]
BS T240 1 DOF Y/V = -0.447 [V]
BS T240 3 DOF Y/V = -0.368 [V]
BS T240 3 DOF Z/W = -0.564 [V]
HAM8 1 DOF Z/W = -0.43 [V]

All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = 0.171 [V]
ETMX T240 1 DOF Y/V = 0.122 [V]
ETMX T240 1 DOF Z/W = 0.127 [V]
ETMX T240 2 DOF Z/W = -0.272 [V]
ETMX T240 3 DOF X/U = 0.097 [V]
ETMX T240 3 DOF Y/V = 0.079 [V]
ETMX T240 3 DOF Z/W = 0.105 [V]
ETMY T240 1 DOF X/U = 0.025 [V]
ETMY T240 1 DOF Y/V = 0.052 [V]
ETMY T240 1 DOF Z/W = 0.128 [V]
ETMY T240 2 DOF X/U = -0.083 [V]
ETMY T240 2 DOF Y/V = 0.148 [V]
ETMY T240 2 DOF Z/W = 0.06 [V]
ETMY T240 3 DOF X/U = 0.134 [V]
ETMY T240 3 DOF Y/V = 0.042 [V]
ETMY T240 3 DOF Z/W = 0.091 [V]
ITMX T240 1 DOF Y/V = 0.278 [V]
ITMX T240 2 DOF X/U = 0.1 [V]
ITMX T240 2 DOF Y/V = 0.195 [V]
ITMX T240 2 DOF Z/W = 0.184 [V]
ITMX T240 3 DOF Y/V = 0.106 [V]
ITMX T240 3 DOF Z/W = 0.133 [V]
ITMY T240 1 DOF X/U = 0.036 [V]
ITMY T240 1 DOF Y/V = -0.017 [V]
ITMY T240 1 DOF Z/W = -0.144 [V]
ITMY T240 2 DOF X/U = 0.074 [V]
ITMY T240 2 DOF Y/V = 0.133 [V]
ITMY T240 2 DOF Z/W = -0.032 [V]
ITMY T240 3 DOF Y/V = 0.003 [V]
BS T240 1 DOF X/U = -0.237 [V]
BS T240 1 DOF Z/W = 0.001 [V]
BS T240 2 DOF X/U = -0.179 [V]
BS T240 2 DOF Y/V = -0.074 [V]
BS T240 2 DOF Z/W = -0.239 [V]
BS T240 3 DOF X/U = -0.284 [V]
HAM8 1 DOF X/U = -0.215 [V]
HAM8 1 DOF Y/V = -0.206 [V]
 
STS:
 
There are 2 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -4.071 [V]
STS EY DOF Z/W = 2.637 [V]

All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.577 [V]
STS A DOF Y/V = -0.784 [V]
STS A DOF Z/W = -0.572 [V]
STS B DOF X/U = 0.513 [V]
STS B DOF Y/V = 0.924 [V]
STS B DOF Z/W = -0.585 [V]
STS C DOF X/U = -0.404 [V]
STS C DOF Y/V = 0.83 [V]
STS C DOF Z/W = 0.247 [V]
STS EX DOF X/U = -0.149 [V]
STS EX DOF Y/V = 0.082 [V]
STS EX DOF Z/W = 0.087 [V]
STS EY DOF Y/V = 0.022 [V]
STS FC DOF X/U = 0.375 [V]
STS FC DOF Y/V = -0.8 [V]
STS FC DOF Z/W = 0.736 [V]
Displaying report 1-1 of 1.