Reports until 09:57, Saturday 05 August 2023
H1 CDS
david.barker@LIGO.ORG - posted 09:57, Saturday 05 August 2023 - last comment - 10:57, Saturday 05 August 2023(71981)
DAQ frames-0 zpool scrub completed

WP11343

root@h1daqframes-0:~# zpool status
  pool: frames-0
 state: ONLINE
  scan: scrub repaired 0B in 3 days 21:34:56 with 0 errors on Sat Aug  5 05:46:41 2023
 

Comments related to this report
david.barker@LIGO.ORG - 10:57, Saturday 05 August 2023 (71984)

During this scrub we had several FW0 frame writing slowdowns. In each case FW0 caught up and all frames were written. The reason for this is that even though the control room default NDS reads from FW1's frames, the LDAS primary frame source is currently FW0.

Mitigation options:

Move both NDS and LDAS to the other FW when performing a scrub.

Scrub less often than 6 times a year, perhaps twice a year during commissioning breaks.