TITLE: 08/06 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Aligning
INCOMING OPERATOR: Austin
SHIFT SUMMARY:
Currently working through an inital alignment
15:00UTC Detector down due to power glitch at 13:34UTC; Ryan S going to CER to turn High Voltage back on (72000)
15:15 Relocking
- Had issues with relocking because the OMC High Voltage PZT were not reset after the power outage (72003)
17:43 Continuing up
18:05 NOMINAL_LOW_NOISE
18:28 Observing
20:33 Earthquake mode activated
20:44 Back to CALM
22:28 Lockloss (72010)
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 13:54 | OPS | Ryan S | HEADING TO SITE | - | Investigating PSL issue | 14:54 |
| 14:56 | PSL | Ryan S | CER | - | Turning on PMC HV | 15:23 |
| 17:11 | OMC | Oli | LVEA | n | Turning HAM6 High Voltage back on | 17:52 |