Taking advantage of the fact that we're not locked, I put the missing ETMX "HFPole" filter module (LHO:72030) back in the H1CAL-CS_DARM_ANALOG_ETMX_L3 filterbank. From inspecting the filter archive, it looks like the "HFpole" ETMX filter module was removed on 4/25/2023. This is around the time we were rolling out the cmd-dev infrastructure for the calibration group.
The plan is to follow up with a Broadband measurement later tonight or at the earlier opportunity to establish whether or not to keep this filter in place.
The zpk string I used is zpk([], [3226.75],1,"n"). The value 3226.75 was calculated by summing the poles for all four ESD quadrants from LHO:46773 as per LHO:27150.
I've attached screenshots of the ETMX filterbank and the GDS TP window.
GDS table diff
324c324
< # DESIGN CS_DARM_ANALOG_ETMX_L3 2 zpk([],[3226.75],1,"n")
---
> # DESIGN CS_DARM_ANALOG_ETMX_L3 2 zpk([],[],9.787382864894167e-13,"n")
343c343
< CS_DARM_ANALOG_ETMX_L3 2 21 1 0 0 HFPole 4.158812836234200838170239e-01 -0.1682374327531596 0.0000000000000000 1.0000000000000000 0.0000000000000000
---
> CS_DARM_ANALOG_ETMX_L3 2 21 1 0 0 TEST_Npct_50W 9.787382864894166725851836e-13 0.0000000000000000 0.0000000000000000 0.0000000000000000 0.0000000000000000