Reports until 07:21, Tuesday 08 August 2023
H1 ISC
corey.gray@LIGO.ORG - posted 07:21, Tuesday 08 August 2023 - last comment - 08:17, Tuesday 08 August 2023(72054)
H1 Lockloss and ALS-X PLL Issues

H1 went down at 1327utc (627amPT), and it definitely had ALSX issues---ALS_XARM guardian node was in a FAULT state.

The camera flashes & ALS x Transmitted channel looked noisy.

Tried a few items on the PLL / ALS_CUST_LASER_LOCKING.adl screen, but none made any changes for the better.  What I tried:

Due to automation, I also was also fighting an INITIAL ALIGNMENT at some point.  Taking H1 to DOWN for the morning crew.

Comments related to this report
ryan.short@LIGO.ORG - 08:17, Tuesday 08 August 2023 (72056)

I was able to fix the ALS X PLL by setting the crystal frequency to 0 MHz and waiting for the autolocker for about 30 seconds. The beatnote is now settled at 39.46 MHz.