Displaying report 1-1 of 1.
Reports until 16:42, Wednesday 24 July 2013
H1 SEI
hugo.paris@LIGO.ORG - posted 16:42, Wednesday 24 July 2013 (7206)
NEW HAM-ISI Blend Filters

Upon Jeff's recommendation I made a new set of blend filters for HAM-ISI that feature:

I installed those filters on HAM3-ISI and compared the isolation performance with what we had before. Plots are attached.  

The new set of blend filters help us meeting the requirements below 1Hz, while still keeping motion within requirements above.

 

Those blend filters are currently installed in the filter bank 9, as "R_eLigo"

The Script I made to create those blend filters is commited under the the SVN (r7461):   /svn/seismic/HAM-ISI/Common/Blend_filters/makeHAMISIBlendFilters_Hybrid.m
The resulting set of filters is commited under the SVN (r7462):                                         /svn/seismic/HAM-ISI/Common/Blend_filters/Filters_HAMISI_Blend_Hybrid_24_Jul_2013.mat

Images attached to this report
Non-image files attached to this report
Displaying report 1-1 of 1.