richard.savage@LIGO.ORG - posted 13:49, Tuesday 08 August 2023 - last comment - 14:15, Thursday 17 August 2023(72063)
Movement of Pcal Xend upper beam position to test impact on Pcal X/Y comparison

Julianna Lewis, TonyS, RickS

This morning we moved the upper (inner) Pcal beam at X-end down by 5 mm at the entrance aperture of the Pcal Rx sensor to test the impact on the calibration of the Pcal system at X-end.

We expect that the impact on the calibration of the Xend Pcal will be given by the dot product of the 

The work proceedes as follows:

We expect that this upper beam movement will change the unintended rotation of the test mass and change the calibration of the Rx output by about 0.2 % This assumes that we have moved at roughly 45 deg. with respect to the roughly 22 mm interferometer beam offset and that the offset on the surface of the ETM is roughly half of that seen at the Rx module: - 2.5 mm / 2 x 22 mm x 0.707 x 0.94 hop / mm^2 = -18 hop (hundreths of one percent).  So we expect to see that X/Y comparison factor will change from about 1.000 to 0.9982.

Images attached to this report
Comments related to this report
richard.savage@LIGO.ORG - 14:15, Thursday 17 August 2023 (72300)

The sign of expected change in the X/Y calibration ratio is opposite to what is written in this entry.

The change observed (after minus before) should be given by: 1/2 \vec{c} dot \vec{b} x M/I.  For a vertical displacement of a Pcal beam (c_y), this reduces to M/2I x c_y x b_y.  Thus, a reduction in the X/Y ratio indicates that the sign of the interferometer beam offset is opposite to that of the Pcal beam displacement.

If we move the Pcal beam down and observe a decrease in the X/Y ratio, it would indicate that the intererometer beam is displaced from center in the upward direction.

See this aLog entry