Reports until 11:28, Friday 11 August 2023
H1 PSL
ryan.short@LIGO.ORG - posted 11:28, Friday 11 August 2023 (72155)
PSL Status Report - Weekly

FAMIS 25491


Laser Status:
    NPRO output power is 1.83W (nominal ~2W)
    AMP1 output power is 67.19W (nominal ~70W)
    AMP2 output power is 134.8W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN

PMC:
    It has been locked 5 days, 3 hr 15 minutes
    Reflected power = 17.33W
    Transmitted power = 108.6W
    PowerSum = 125.9W

FSS:
    It has been locked for 0 days 1 hr and 45 min
    TPD[V] = 0.9241V

ISS:
    The diffracted power is around 2.1%
    Last saturation event was 0 days 1 hours and 45 minutes ago


Possible Issues: None