HIFOY left locked on red light
HIFOY was left locked on red light tonight. The clean lock is starting at 08:19 UTC on 07/25/2013.

The main error signal is H1:LSC-CARM_IN1_DQ. It is calibrated in Hz Green (but not closed loop corrected - for that see my other log entry).

The noise seen by the channel is most likely IMC noise, but checking for correlations with ETMY, ITMY and their ISI's is also worth it.
Comments related to this report
jeffrey.kissel@LIGO.ORG - 01:36, Thursday 25 July 2013 (7221)
Here're the configurations of the relevant seismic isolation systems:

Chamber    HEPI                                   ISI                               SUS
HAM1       Locked                                 n/a                               n/a
HAM2       Floating, Alignment Offsets Only       Level 2 Isolated                  MC1, MC3, PRM damped Level 1.5; PR3 damped Level 1.0
HAM3       Floating, Alignment Offsets Only       Level 2 Isolated (eLIGO Blends)  MC2, PR2 damped Level 1.5 
BS         Level 2 Isolated (Position Locked)     Damping Only                      BS damped Level 2.0
ITMY       Locked                                 Damping Only                      ITMY damped Level 2.1
ETMY       Level 2 Isolated (Position Locked)     Damping Only                      ETMY damped Level 2.1, TMSY damped Level 2.0