Displaying report 1-1 of 1.
Reports until 19:15, Monday 14 August 2023
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 19:15, Monday 14 August 2023 - last comment - 23:51, Monday 14 August 2023(72209)
Lockloss

Lockloss at 2:09UTC. Got an EX saturation callout immediately before.

In relocking, I will be setting ISC_LOCK so we go to LOWNOISE_LENGTH_CONTROL instead of straight to NOMINAL_LOW_NOISE, to see if the 102Hz line is caused by LOWNOISE_LENGTH_CONTROL or by the calibration lines engaging at TURN_ON_CALIBRATION_LINES (72205).

Comments related to this report
oli.patane@LIGO.ORG - 23:51, Monday 14 August 2023 (72216)DetChar

I noticed a weird set of glitches on the glitchgram fom that took place between 3:13 and 3:57UTC(spectrogram, omicron triggers), ramping up in frequency from 160-200Hz over that timespan. Even though we weren't Observing when this was happening, the diagonal line on many of the summary page plots is hard to miss and so I wanted to post this and tag DetChar to give info as to why these glitches appeared and why they (presumably) shouldn't be seen again.

This is after we had reached NOMINAL_LOW_NOISE but were not Observing yet due to waiting for ADS to converge. Although I don't know the direct cause of these glitches, them appearing, along with ADS not converging, was because I had selected the wrong state to pause at before going into LOWNOISE_LENGTH_CONTROL(for 102Hz peak test), so even though I was then able to proceed to NOMINAL_LOW_NOISE, the detector wasn't in the correct configuration. Once we lost lock trying to correct the issue, relocking automatically went through the correct states. So these glitches occurred during a non-nominal NOMINAL_LOW_NOISE.

Images attached to this comment
Displaying report 1-1 of 1.