Displaying report 1-1 of 1.
Reports until 12:53, Friday 18 August 2023
H1 DetChar (DetChar)
joseph.talucci@LIGO.ORG - posted 12:53, Friday 18 August 2023 (72323)
Frequency shifts over time for 9.474, 9.475, 9.480Hz combs
I tracked how various combs in the strain channel have changed in frequency over time using the autolines-complete.txt files for the daily FSCAN spectra (TSFT 1800s). I found that the 9.474, 9.475, and 9.480Hz combs have been changing in frequency over the course of O4, and have identified some key dates that warrant further investigation. I tracked the combs' frequency-roaming behavior by selecting a tooth which appeared often and was high-frequency. This was n=65 for the 9.474Hz comb, n=70 for the 9.475Hz comb, and n=64 for the 9.480Hz comb. The graphs of frequency over time I generated are available below. 

Observations:
The 9.474Hz comb's n=65 harmonic initially increases in frequency from 05-24 to 06-05, and then sharply drops from 06-22 to 06-24
The 9.475Hz comb's n=70 harmonic initially increases sharply in frequency from 05-26 to 06-05, and then sharply drops from 06-21 to 06-23
The 9.480Hz comb's n=64 harmonic initially increases sharply in frequency from 05-30 to 06-05, and then sharply drops from 06-22 to 06-23

So it seems that all three combs' frequencies begin increasing in very early O4 until 06-05 and then abruptly decrease from 06-21 to 06-24. It's likely that the combs were affected by changes made to the interferometer during these periods -- I believe that the week of 06-21 (Sunday) was when we set the power back down to 60Hz. 

I checked several other combs as well (n=11 of 4.98423, n=13 of 29.96518, n=161 of 1.6611, and n=3 of 11.9044) and none of those have observable changes in frequency (they may still be roaming inside their frequency bins) so this feature seems fairly unique to the 9.4Hz family.
Images attached to this report
Displaying report 1-1 of 1.