jenne.driggers@LIGO.ORG - posted 10:43, Friday 18 August 2023 - last comment - 13:51, Friday 18 August 2023(72319)
New thing to try for lownoise length control

Since we have to relock, I've switched the order of items in lownoise length control, so that we will change the main LSC gains first, then turn on the FF.  Hopefully that will address the issue that Daniel hypothesises is our problem, and we won't ring up the 102 Hz line.  If this does not work, do something like an

svn up ISC_LOCK.py

in the userapps/isc/h1/guardian/ folder to reveret to the previous file (which I had checked in just before I made this mod).  I have not checked in ISC_LOCK.py with this modification yet.

Comments related to this report
elenna.capote@LIGO.ORG - 12:28, Friday 18 August 2023 (72322)

This *may* have helped, in that the resulting 102 Hz line was smaller during this relock.

This is a quick comparison plot of DARM around 102 Hz from the relock we just had (with reordered guardian steps), and the previous relock with the normal order of guardian steps. Both times I chose are the times when the guardian state number changed to 600 (entering nominal low noise).

 

Images attached to this comment
jenne.driggers@LIGO.ORG - 13:51, Friday 18 August 2023 (72325)

Since this seems to have worked (at least it didn't hurt / we were able to lock), I have now committed this to the svn.