victoriaa.xu@LIGO.ORG - posted 15:32, Wednesday 23 August 2023 (72390)
Sqz tests today, higher NLG didn't improve sqz much, changed FC detuning from -25 to -28 Hz

Naoki, Vicky

Today we tested higher generated SQZ level and FC detuning, summary screenshot here. We turned up non-linear gain from NLG 11 to 17, so gen sqz level from 14.7dB to 17dB, and very barely got more sqz (< 0.2dB?). We set it back to the "normal" 80uW operating point, leaving the injected sqz level unchanged. We ended up changing FC detuning from -25 Hz to -28 Hz. Notes:

Images attached to this report