Displaying report 1-1 of 1.
Reports until 15:55, Wednesday 23 August 2023
H1 CAL
louis.dartez@LIGO.ORG - posted 15:55, Wednesday 23 August 2023 - last comment - 16:09, Wednesday 23 August 2023(72394)
reduced amplitude of PCALY 17.1Hz calibration line
I reduced the amplitude of the 17.1 Hz PCALY calibration line. This is a continuation of LHO:71945.



Channel                                                             Old Gain            New Gain            Reduction Factor
=================                                     =========        ===========        ===========
H1:CAL-PCALY_PCALOSC1_OSC_SINGAIN          250                   115                              2.17


The changes have been saved to observe and safe snap files in the SDF system.
Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 16:09, Wednesday 23 August 2023 (72396)

Louis double checked, and these are not touched by Guardian, so with these SDF saves everything should come back just fine next lock.

Displaying report 1-1 of 1.