david.barker@LIGO.ORG - posted 10:34, Sunday 27 August 2023 - last comment - 10:44, Sunday 27 August 2023(72469)
Single DAQ CRC error for h1sush2b, recorded by DC0, at 05:56:09 PDT

As Corey mentioned, the DAQ stream from h1sush2b to DC0 had a checksum mismatch in one of its 1/16th second data blocks during the  05:56:09 PDT second. The data stream to DC1 did not see this issue.

This was a true data error for this data block, which meant that FW0 wrote a different frame than FW1 for the frame which encompassed this 1/16th of a second. We know that FW1's frame is correct, FW0's frame has bad h1sush2b data.

For the full frame file H-H1_R-1377176128-64.gwf:

FW SIZE (bytes) CKSUM
FW0 2115565285 4100757796
FW1 2115562427 1319327622

Interestingly the correct frame is smaller than the bad frame, meaning the corrupt signal did not compress as well as the actual signal.

Comments related to this report
david.barker@LIGO.ORG - 10:44, Sunday 27 August 2023 (72471)
Displaying report 1-1 of 1.