OPS Wednesday day shift summary

TITLE: 08/30 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 149Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

Lock#1:

Lockloss at 16:18UTC

The squeezer kept losing lock all morning, and the ISS saturated.

Lock#2:

After some investigation while we were relocking it was found that FC1 was having troubles, Fil power cycled the chassis and then swapped the coil driver and satellite box for a spare. But none of these actions were successful to fix the issue.

We required NLN at 17:52, but we stayed out of Observing while the FC1 investigation/work was ongoing. It was narrowed down to an issue with the T3 BOSEM on FC1. An old (2011) ADC card ended up being swapped for a new one (2021) which was the root of issue! Fil swapped back the original coil drivers and satellite box. Alog72558 documenting the process

I took a broadband and simulines calibration measurement during the investigation time, then a second one later on in the afternoon.

Back into Observing at 22:46UTC after squeezer commissioning and MICHFF testing.                                                              

LOG:                                       

Start Time System Name Location Lazer_Haz Task Time End
15:25 FAC Cindy MidX N Tech clean 16:53
17:39 EE Fil CER N Investigate FC1 17:51
17:59 EE Fil MidY N Get a spare satellite box 18:22
18:22 EE Fil CER N Coil driver, Satellite box swap FC1 18:50
18:50 FAC Cindy Mech room N Tech clean 19:37
19:40 SUS Fil, Rahul CER N Investigate whether to replace AA chassis 20:07
19:41 FAC Cindy H2 N Tech clean 19:58
19:50 LSC Elenna Remote N Test new MICHFF, OMC injection 20:19
20:15 EE Fil, Dave MSR, CER N HAM7 FC1 AA chassis swap, restore swapped parts (Coil drivers, satellite box) 20:40
20:42 ASC Elenna Remote N Measurments, 8Hz line 21:20
20:45 SQZ Vicky, Sheila, Naoki CR N SQZ commissioning 22:28
21:16 FAC Randy LVEA, west bay N Grab parts 21:21
22:19 FAC Tyler EndY chiller yard N Check on chiller 22:33
22:37 LSC Elenna, Camilla Remote N Test new filter 22:45
Displaying report 1-1 of 1.