Displaying report 1-1 of 1.
Reports until 12:39, Wednesday 30 August 2023
H1 CAL
ryan.crouch@LIGO.ORG - posted 12:39, Wednesday 30 August 2023 - last comment - 15:17, Wednesday 30 August 2023(72560)
CAL BB and Simulines measurement

I ran a calibration sweep this afternoon, starting with the broadband:

/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20230830T190736Z.xml

Simulines:

2023-08-30 19:36:43,647 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20230830T191430Z.hdf5
2023-08-30 19:36:43,663 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20230830T191430Z.hdf5
2023-08-30 19:36:43,674 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20230830T191430Z.hdf5
2023-08-30 19:36:43,684 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20230830T191430Z.hdf5
2023-08-30 19:36:43,696 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20230830T191430Z.hdf5

GPS start: 1377458086.806734

GPS stop: 1377459422.017018

 

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 13:04, Wednesday 30 August 2023 (72564)

This is the first calibration measurement with the new DARM boost filter (alog 72565)

jeffrey.kissel@LIGO.ORG - 15:17, Wednesday 30 August 2023 (72574)ISC
... however, we realized too late that the IFO had not yet thermalized during this measurement. As such, we're not confident that this measurement will convey a representative sensing function suitable for an update to the calibration pipeline parameters.

So, we will likely throw this *sensing* measurement in the "not yet thermalized" bin. 
It is still a totally fine actuation measurement.

For a more thermalized measurement in the same IFO configuration a few hours later -- see LHO:72573.

Attached shows a trend of the TDCFs (specifically the relative optical gain, \kappa_C, and cavity pole frequency, f_CC -- second and third rows) vs. the arm cavity power (bottom row).

The first dashed vertical line is the start of this measurement's time.
The second dashed vertical line is the start of the LHO:72573 measurement.
The arm cavity power is much more like the previous stretch's thermalized arm power at the second vertical dashed line, and less "on the exponential rise." One can see this *less* so in the \kappa_C and f_CC trend, but we feel it better to be safe than sorry and use the LHO:72573 measurement 2.5 hours later.
Images attached to this comment
Displaying report 1-1 of 1.