Reports until 16:36, Wednesday 30 August 2023
H1 SUS
ryan.short@LIGO.ORG - posted 16:36, Wednesday 30 August 2023 - last comment - 16:50, Wednesday 30 August 2023(72580)
In-Lock SUS Charge Measurement - Weekly

FAMIS 26055, last run in alog 72310

Most V_eff values are trending upwards while a few are staying flat, with ETMX's increase being the most dramatic (more noticeable likely because the ETMX measurement has not been run in over a month according to this week's plot).

Images attached to this report
Comments related to this report
ryan.short@LIGO.ORG - 16:50, Wednesday 30 August 2023 (72581)

Thanks goes to Camilla for pointing out that I should've been paying attention to the y-axes on the V_eff value plots. Although many of them are indeed trending upwards, they are also moving towards zero, so there's little cause for concern.