Displaying report 1-1 of 1.
Reports until 13:33, Monday 28 August 2023
H1 SQZ
daniel.sigg@LIGO.ORG - posted 13:33, Monday 28 August 2023 - last comment - 10:59, Tuesday 05 September 2023(72490)
Squeezer Laser Diode Nominal Current Changed

The nominal value of the squeezer laser diode current was change to 1.863 from 1.95. The tolerance is unchanged at 0.1. Looking at trends we sometimes read a value just below 1.85 leading to a failed laser condition which in turn triggers a relocking of the squeezer laser. However, since we are already locked, all we see is the fast and commen gains ramping down and up.

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 13:50, Monday 28 August 2023 (72491)

Looking at this diode current trend over the past 500 days, we see it fairly stable but trending down very slowly. It may have lost 10 mA over the past year. Resetting the nominal value should keep us in the good band for a while if this trend continues.

Images attached to this comment
victoriaa.xu@LIGO.ORG - 17:58, Wednesday 30 August 2023 (72584)

So far this seems to have fixed the TTFSS gain changing issue! Haven't seen gain changes while locked in the past couple days, since Daniel changed the laser diode nominal current (bottom purple trend).

Images attached to this comment
daniel.sigg@LIGO.ORG - 10:59, Tuesday 05 September 2023 (72679)

In the past week there wasn't single TTFSS gain ramping incident during lock. The fast and common gains are again monitored in SDF.

Images attached to this comment
Displaying report 1-1 of 1.